The line-interactive EP UPS is compact and provides stable power protection against surges and spikes. It is ideal for PC users or small business companies, as well as for small telecom applications. Its embedded microprocessor controller guarantees high reliability.
It can automatically shut down without any load and restart while AC power is recovering. With Simulated sine wave, cold start function, and USB/RS-232 communication port and RJ-11 phone protection, it will be a good choice.
Features:
- Excellent microprocessor control guarantees high reliability
- Boost and buck AVR for voltage stabilization
- No load auto shutdown
- Auto restart while AC is recovering
- Simulated sine wave
- Off-mode charging
- Cold start function
- Optional USB/RS-232 communication port and RJ-11 phone protection
Backup Time Table:
Model | Backup Time when the load connected to the UPS. Percentage load corresponding to the UPS maximum power. | |||
25% | 50% | 75% | 100% | |
EP 650 (650VA/360W) | 19 min. | 6 min. | 30 sec. | 5 sec. |
EP 850 (850VA/480W) | 20 min. | 3 min. | 8 sec. | 5 sec. |
EP 1000 (1000VA/600W) | 25 min. | 7 min. 30 sec. | 1 min. | 30 sec. |
EP 1500 (1500VA/900W) | 20 min. | 6 min. 30 sec. | 2 min. | 1 min. 20sec. |
EP 2000 (2000VA/1200W) | 15 min. | 5 min. | 2 min. | 1 min. |
Specifications:
Model | EP 650 | EP 850 | EP 1000 | EP 1500 | EP 2000 |
Capacity | 650 VA / 360W | 850 VA / 480W | 1000 VA / 600W | 1500 VA / 900 W | 2000 VA / 1200 W |
Available Factory Settings | 110 / 120 VAC or 220 / 230 / 240 VAC | ||||
Input Voltage Range | 81-145 / 162-290 VAC | ||||
Input Frequency | 60/50 Hz (auto sensing) | ||||
Output Voltage | 220V nominal | ||||
Output Frequency Range | 50 Hz or 60 Hz ±1 Hz | ||||
Output Transfer Time (Typical) | Typical 2-6 ms, 10ms max. | ||||
Output Waveform (Batt. Mode) | Simulated Sine Wave | ||||
Battery Type & Number | 12 V/ 4.5 AH x 1 | 12 V/ 4.5 AH x 1 | 12 V/ 7 AH x 2 | 12 V/ 9 AH x 2 | 12 V/ 9 AH x 2 |
Backup Time (One PC load@120W) | 10 min. | 15 min. | 20 min. | 25 min. | 30 min. |
Typical Recharge Time | 4-6 hours recover to 90% capacity | ||||
Indicators / AC Mode | Green lighting | Right green LED lighting and the 2nd to 5th green LEDs gradually lighting indicating load level | |||
Indicators / Battery Mode | Green flashing | Green flashing | Yellow flashing | Right green LED flashing and the 2nd to 5th green gradually lighting indicating battery capacity | |
Indicators / Fault | ✘ | ✘ | ✘ | Red lighting | |
Overload Protection | ✔ | ||||
Discharge Protection | ✔ | ||||
Overcharge Protection | ✔ | ||||
Alarm / Battery Mode | Sounding every 10 seconds | ||||
Alarm / Low Battery | Sounding every second (Batt. Mode) | ||||
Alarm / Overload | Sounding twice per second | ||||
Alarm / Battery Replacement Alarm | Sounding every 2 seconds | ||||
Alarm / Fault | Continuously sounding | ||||
Outlet Sockets | Schuko, NEMA, and IEC selections | Schuko x 3 + IEC x 3/ also provide India, French, Schuko, NEMA, and IEC for selections | |||
Dimensions (WxHxL @ vertical stand) mm | 110 x 145 x 294 | 145 x 165 x 345 | 146 x 205 x 397 | ||
Physical Net Weight (kg) | 4.25 | 4.9 | 8 | 11.1 | 11.5 |
Operating Environment / Humidity | 0-90% RH @ 0-40°C (non-condensing) | ||||
Operating Environment / Noise Level | Less than 40dB | ||||
Management / Optional USB / RS-232 Port | Supports Windows® 98/2000/2003/XP/Vista/2008, Windows® 7, Linux, and MAC |